12
6.5 Controlling the Scanner from a POS System
The scanner can be controlled from the POS system via the RS-232C interface.
Control can be accomplished by transmitting the following single-byte com
-
mands to the scanner. The default settings for the commands are as follows:
Note: When the scanner is disabled, the scanner motor will continue running
until the scanner goes into sleep mode.
ASCII
Code
Function
Byte is Also
Called:
OE Hex enable (resumes from disable) Shift Out or <Ctrl-N>
OF Hex disable Shift In or <Ctrl-O>
05 Hex power-up re-initialization ENQ or <Ctrl-E>
12 Hex sleep DC2 <Ctrl-R>
14 Hex wake up (resumes sleep) DC4 <Ctrl-T>